{"title":"Pressure Sensors","description":"","products":[{"product_id":"maretron-pt-0-1000psi-01","title":"Pressure Transducer (0-1000 psi)","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMaretron Pressure Transducer — 0 to 1,000 PSI, Gauge Type (PT-0-1000PSI-01)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eA high-range gauge-type transducer that connects to a Maretron FPM100 Fluid Pressure Monitor to put pressure readings on your NMEA 2000 network — sized for high-pressure hydraulic steering, stabilizers, and similar high-pressure marine systems.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhy It's Worth It\u003c\/strong\u003e\u003cbr\u003eFor maximum accuracy, always use the transducer with the smallest range sufficient for your application — a 0-1000 PSI transducer on an 800 PSI hydraulic system gives you far better resolution than the 5000 PSI unit on the same circuit. This gauge-type transducer measures pressure relative to atmospheric (not absolute), and has a vent tube in the connecting cable to maintain that reference — keep the vent tube end dry and unkinked or readings will drift. At this pressure range, a PT-SNUB-01 pressure snubber is strongly recommended to protect the transducer from hydraulic spikes and surges.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003cbr\u003eThread into any 1\/4\" NPT female fitting. Install torque 133-177 in-lbs (15-20 Nm). Install a PT-SNUB-01 pressure snubber first when monitoring spike-prone systems such as hydraulics, then thread the transducer into the snubber's outlet. Connect the white wire to the positive (+) terminal and the brown wire to the negative (-) terminal of a free FPM100 channel. Not approved for use with gasoline.\u003c\/p\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":45225937109174,"sku":"MAR\/PT-0-1000PSI-01","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/MARPT01000PSI01_001.jpg?v=1783452599"},{"product_id":"maretron-pt-0-100psi-01","title":"Pressure Transducer (0-100 psi)","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMaretron Pressure Transducer — 0 to 100 PSI, Gauge Type (PT-0-100PSI-01)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eA mid-range gauge-type transducer that connects to a Maretron FPM100 Fluid Pressure Monitor to put pressure readings on your NMEA 2000 network — sized for engine oil pressure, fuel pressure, and similar mid-range marine systems.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhy It's Worth It\u003c\/strong\u003e\u003cbr\u003eFor maximum accuracy, always use the transducer with the smallest range sufficient for your application — a 0-100 PSI transducer on an 80 PSI system gives you far better resolution than a higher-range unit on the same circuit. At this range, accuracy steps up to ±0.5% Full Scale (vs. ±2% on the lower-range units), making it well suited for engine monitoring applications where precise readings matter. This gauge-type transducer measures pressure relative to atmospheric (not absolute), and has a vent tube in the connecting cable to maintain that reference — keep the vent tube end dry and unkinked or readings will drift.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003cbr\u003eThread into any 1\/4\" NPT female fitting. Install torque 133-177 in-lbs (15-20 Nm). If the monitored system is subject to pressure spikes or transients, install a PT-SNUB-01 pressure snubber first, then thread the transducer into the snubber's outlet. Connect the white wire to the positive (+) terminal and the brown wire to the negative (-) terminal of a free FPM100 channel. Not approved for use with gasoline.\u003c\/p\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":45225937141942,"sku":"MAR\/PT-0-100PSI-01","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/MARPT0100PSI01_001.jpg?v=1783452530"},{"product_id":"maretron-pt-0-10psi-01","title":"Pressure Transducer (0-10 psi)","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMaretron Pressure Transducer — 0 to 10 PSI, Gauge Type (PT-0-10PSI-01)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eA low-range gauge-type transducer that connects to a Maretron FPM100 Fluid Pressure Monitor to put pressure readings on your NMEA 2000 network — sized for low-pressure monitoring applications like water pressure, HVAC, or air systems in the 0-10 PSI range.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhy It's Worth It\u003c\/strong\u003e\u003cbr\u003eFor maximum accuracy, always use the transducer with the smallest range sufficient for your application — a 0-10 PSI transducer on an 8 PSI system gives you far better resolution than a higher-range unit on the same circuit. This gauge-type transducer measures pressure relative to atmospheric (not absolute), and has a vent tube in the connecting cable to maintain that reference — keep the vent tube end dry and unkinked or readings will drift.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003cbr\u003eThread into any 1\/4\" NPT female fitting. Install torque 133-177 in-lbs (15-20 Nm). If the monitored system is subject to pressure spikes or transients, install a PT-SNUB-01 pressure snubber first, then thread the transducer into the snubber's outlet. Connect the white wire to the positive (+) terminal and the brown wire to the negative (-) terminal of a free FPM100 channel. Not approved for use with gasoline.\u003c\/p\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":45225937174710,"sku":"MAR\/PT-0-10PSI-01","price":195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/MARPT010PSI01_001.jpg?v=1783452449"},{"product_id":"maretron-pt-0-3psi-01","title":"Pressure Transducer (0-3 psi)","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMaretron Pressure Transducer — 0 to 3 PSI, Gauge Type (PT-0-3PSI-01)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe lowest-range gauge-type transducer in Maretron's FPM100 lineup — sized for very low-pressure monitoring applications like tank air pressure, low-pressure water systems, or HVAC monitoring.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhy It's Worth It\u003c\/strong\u003e\u003cbr\u003eFor maximum accuracy, always use the transducer with the smallest range sufficient for your application — a 0-3 PSI transducer on a 2.5 PSI system gives you far better resolution than any higher-range unit on the same circuit. This gauge-type transducer measures pressure relative to atmospheric (not absolute), and has a vent tube in the connecting cable to maintain that reference — keep the vent tube end dry and unkinked or readings will drift.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003cbr\u003eThread into any 1\/4\" NPT female fitting. Install torque 133-177 in-lbs (15-20 Nm). If the monitored system is subject to pressure spikes or transients, install a PT-SNUB-01 pressure snubber first, then thread the transducer into the snubber's outlet. Connect the white wire to the positive (+) terminal and the brown wire to the negative (-) terminal of a free FPM100 channel. Not approved for use with gasoline.\u003c\/p\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":45225937207478,"sku":"MAR\/PT-0-3PSI-01","price":195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/MARPT03PSI01_001.jpg?v=1783452349"},{"product_id":"maretron-pt-0-5000psi-01","title":"Pressure Transducer (0-5000 psi)","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMaretron Pressure Transducer — 0 to 5,000 PSI, Absolute Type (PT-0-5000PSI-01)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe highest-range transducer in Maretron's FPM100 lineup — sized for very high-pressure hydraulic systems, watermakers, and other extreme-pressure marine applications, and the only absolute-type unit in the range.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhy It's Worth It\u003c\/strong\u003e\u003cbr\u003eFor maximum accuracy, always use the transducer with the smallest range sufficient for your application — only use this 5000 PSI unit when your system actually operates near this range. Unlike the lower-range gauge-type transducers, this unit is absolute-type, meaning it measures total pressure rather than pressure relative to atmosphere. There's no vent tube in the cable — a simpler installation with no vent tube to protect, but a different output reference to account for when configuring the FPM100. At this pressure range, a PT-SNUB-01 pressure snubber is essential to protect the transducer from hydraulic spikes and surges.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003cbr\u003eThread into any 1\/4\" NPT female fitting. Install torque 150 in-lbs (16.95 Nm) — note the slightly higher torque spec vs. lower-range units (133-177 in-lbs). Install a PT-SNUB-01 pressure snubber first when monitoring spike-prone systems, then thread the transducer into the snubber's outlet. Connect the white wire to the positive (+) terminal and the brown wire to the negative (-) terminal of a free FPM100 channel. Not approved for use with gasoline.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":45225937240246,"sku":"MAR\/PT-0-5000PSI-01","price":195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/MARPT05000PSI01_001.jpg?v=1783452175"},{"product_id":"maretron-pt-0-500psi-01","title":"Pressure Transducer (0-500 psi)","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMaretron Pressure Transducer — 0 to 500 PSI, Gauge Type (PT-0-500PSI-01)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eA high-range gauge-type transducer that connects to a Maretron FPM100 Fluid Pressure Monitor to put pressure readings on your NMEA 2000 network — sized for hydraulic steering, hydraulic stabilizers, and other higher-pressure marine systems.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhy It's Worth It\u003c\/strong\u003e\u003cbr\u003eFor maximum accuracy, always use the transducer with the smallest range that's sufficient for your application — a 0-500 PSI transducer on a 400 PSI hydraulic system gives you far better resolution than a 0-3000 PSI unit on the same circuit. This gauge-type transducer measures pressure relative to atmospheric (not absolute), and has a vent tube in the connecting cable to maintain that reference — keep the vent tube end dry and unkinked or readings will drift. At this pressure range, a PT-SNUB-01 pressure snubber is strongly recommended to protect the transducer from hydraulic spikes and surges.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003cbr\u003eThread into any 1\/4\" NPT female fitting. Install torque 133-177 in-lbs (15-20 Nm). Install a PT-SNUB-01 pressure snubber first if monitoring a spike-prone system such as hydraulics, then thread the transducer into the snubber's outlet. Connect the white wire to the positive (+) terminal and the brown wire to the negative (-) terminal of a free FPM100 channel. Not approved for use with gasoline.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":45225937273014,"sku":"MAR\/PT-0-500PSI-01","price":195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/MARPT0500PSI01_001.jpg?v=1783452053"},{"product_id":"maretron-pt-0-50psi-01","title":"Pressure Transducer (0-50 psi)","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMaretron Pressure Transducer — 0 to 50 PSI, Gauge Type (PT-0-50PSI-01)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eA mid-range gauge-type transducer that connects to a Maretron FPM100 Fluid Pressure Monitor to put pressure readings on your NMEA 2000 network — sized for engine oil pressure, raw water pressure, and similar mid-range marine systems.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhy It's Worth It\u003c\/strong\u003e\u003cbr\u003eFor maximum accuracy, always use the transducer with the smallest range that's sufficient for your application — a 0-50 PSI transducer on a 40 PSI system gives you far better resolution than a 0-300 PSI unit on the same circuit. This gauge-type transducer measures pressure relative to atmospheric (not absolute), and has a vent tube in the connecting cable to maintain that reference — keep the vent tube end dry and unkinked or readings will drift.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003cbr\u003eThread into any 1\/4\" NPT female fitting. Install torque 133-177 in-lbs (15-20 Nm). If the monitored system is subject to pressure spikes or transients, install a PT-SNUB-01 pressure snubber first, then thread the transducer into the snubber's outlet. Connect the white wire to the positive (+) terminal and the brown wire to the negative (-) terminal of a free FPM100 channel. Not approved for use with gasoline — use a gasoline-rated transducer for fuel pressure monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":45225937305782,"sku":"MAR\/PT-0-50PSI-01","price":195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/MARPT050PSI01_001.avif?v=1783451947"},{"product_id":"maretron-pt-0-5psi-01","title":"Pressure Transducer (0-5 psi)","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eConfirmed — the PT-0-5PSI-01 is the gauge-type (non-submersible) version, while the PTS-0-5PSI-01 is the submersible version of the same range. Important distinction worth flagging clearly. Confirmed specs from the official installation instruction table: Range 0-5 PSI (0.34 bar), Accuracy ±2% Full Scale, Type Gauge (vented cable). Max installation torque 133-177 in-lbs (15-20 Nm).\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMaretron Pressure Transducer — 0 to 5 PSI, Gauge Type (PT-0-5PSI-01)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eA low-pressure gauge-type transducer that connects to a Maretron FPM100 Fluid Pressure Monitor to put pressure readings on your NMEA 2000 network — sized for monitoring low-pressure systems like bilge, water, or oil pressure at the low end of the scale.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhy It's Worth It\u003c\/strong\u003e\u003cbr\u003eFor maximum accuracy, always use the transducer with the smallest range that's sufficient for your application — a 0-5 PSI transducer on a 5 PSI system gives you far better resolution than a 0-100 PSI unit on the same circuit. This gauge-type transducer measures pressure relative to atmospheric (not absolute), and has a vent tube in the connecting cable to maintain that reference — keep the vent tube end dry and unkinked or readings will drift.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003cbr\u003eThread into any 1\/4\" NPT female fitting. Install torque 133-177 in-lbs (15-20 Nm). If the monitored system is subject to pressure spikes or transients, install a PT-SNUB-01 pressure snubber first, then thread the transducer into the snubber's outlet. Connect the white wire to the positive (+) terminal and the brown wire to the negative (-) terminal of a free FPM100 channel. Not approved for use with gasoline — use a gasoline-rated transducer for fuel pressure monitoring.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This is the gauge-type (non-submersible) version. For tank level monitoring via submersion, use the PTS-0-5PSI-01 instead.\u003c\/p\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":45225937338550,"sku":"MAR\/PT-0-5PSI-01","price":195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/MARPT05PSI01_001.jpg?v=1783451745"}],"url":"https:\/\/ampedupmarine.com\/collections\/pressure-sensors.oembed","provider":"Amped Up Marine","version":"1.0","type":"link"}