{"product_id":"maretron-cbmd12-r","title":"Mpower Bypass Module + Fuse Pack\/Jumper","description":"\u003cdiv class=\"_chunkWrapper_6ta1u_30\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eMaretron MPower CBMD12-R 12-Channel Bypass Module with Jumper Wire and Fuse Pack\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"_chunkWrapper_6ta1u_30\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"0\"\u003eA manual \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"9\"\u003eoverride panel that gives \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"35\"\u003eyou physical switch \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"55\"\u003econtrol over every CLMD12 \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"81\"\u003eload circuit if the NMEA \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"106\"\u003e2000 network fails or \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"128\"\u003ethe CLMD12 itself \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"146\"\u003emalfunctions — 12 Carling \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"172\"\u003eCurvette rocker switches, \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"198\"\u003eindividual ATC fuse \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"218\"\u003eprotection per channel, and no \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"249\"\u003earcing during override.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"_chunkWrapper_6ta1u_30\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eWhy It's Worth It\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eDigital switching \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"40\"\u003esystems are only as \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"60\"\u003ereliable as the network and \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"88\"\u003eelectronics that control them — \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"120\"\u003ewhich is exactly why a \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"143\"\u003ebypass module exists. If \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"168\"\u003ethe CLMD12 loses \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"185\"\u003enetwork communication or \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"210\"\u003efails entirely, the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"230\"\u003eCBMD12 lets you unplug \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"253\"\u003ethe J1 connector from \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"275\"\u003ethe CLMD12 and plug it \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"298\"\u003einto the CBMD12 instead, \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"323\"\u003egiving you direct switch \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"348\"\u003econtrol over every load \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"372\"\u003ewith no network \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"388\"\u003edependency. The Carling Curvette \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"421\"\u003erocker switches are \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"441\"\u003epurpose-built for marine environments \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"479\"\u003e(corrosion, temperature, vibration, and \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"519\"\u003eshock rated) and produce no \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"547\"\u003earcing during switching — a \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"575\"\u003esafety consideration in a bilge \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"607\"\u003eor fuel vapor environment. \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"634\"\u003eATC fuse protection per \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"658\"\u003echannel uses the same current \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"688\"\u003eratings as the CLMD12 outputs, and \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"723\"\u003ethe fuse slot markings \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"746\"\u003eeliminate the need to \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"768\"\u003ecross-reference a chart to install the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"807\"\u003eright fuse. Importantly, \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"832\"\u003ebypass does not require moving or \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"866\"\u003eremoving fuses — a common \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"892\"\u003edegradation point in other bypass \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"926\"\u003eapproaches.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"_chunkWrapper_6ta1u_30\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eImportant Limitations\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eThe CBMD12 \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"37\"\u003edoes not support paralleled outputs or \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"76\"\u003ePWM dimming — if your CLMD12 \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"105\"\u003einstallation uses paralleled circuits \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"143\"\u003eor dimmable lighting, those \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"171\"\u003efeatures are unavailable in bypass \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"206\"\u003emode. Each circuit is controlled \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"239\"\u003eby a separate switch only.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"_chunkWrapper_6ta1u_30\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eUse\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eInstall adjacent to or \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"31\"\u003enear the CLMD12. In normal \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"58\"\u003eoperation, the CBMD12 sits unpowered \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"95\"\u003eand unused — it's strictly a \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"124\"\u003ebackup. To activate bypass: \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"152\"\u003eensure area is free of fumes, \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"182\"\u003eset all CBMD12 switches to \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"209\"\u003eOFF, connect DC power to the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"238\"\u003e1\/4\"-20 stud, unplug J1 from the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"271\"\u003eCLMD12, and plug J1 into the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"300\"\u003eCBMD12. The included red 6AWG \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"330\"\u003ejumper wire (A3720) connects the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"363\"\u003eCBMD12 to the CLMD12's main DC \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"394\"\u003e(+) source when mounted \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"418\"\u003eadjacently. Switch labels on the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"451\"\u003eCBMD12 correspond to CLMD12 \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"479\"\u003ebreaker numbers — not sequential \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"512\"\u003eleft-to-right — so use the label under \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"551\"\u003ethe ABS cover to identify \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"577\"\u003ewhich switch controls which \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"605\"\u003eload.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":45225935044790,"sku":"MAR\/CBMD12-R","price":195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/MARCBMD12R_001.jpg?v=1783529269","url":"https:\/\/ampedupmarine.com\/es\/products\/maretron-cbmd12-r","provider":"Amped Up Marine","version":"1.0","type":"link"}