{"product_id":"victron-energy-lyn034160310","title":"Victron Lynx Smart BMS 500 NG (M10)","description":"\u003cp\u003e\u003cstrong\u003eLynx Smart BMS 500 NG (M10)\u003c\/strong\u003e\u003c\/p\u003e\u003cp id=\"isPasted\"\u003eThe Lynx Smart BMS NG is a dedicated Battery Management System (BMS) designed specifically for the Victron Lithium NG batteries. These batteries utilize Lithium Iron Phosphate (LiFePO4) technology and are available in 12.8 V, 25.6 V, and 51.2 V variants with various capacities. They can be configured in series, parallel, and series\/parallel arrangements, allowing for the creation of battery banks with system voltages of 12V, 24V, or 48V. The maximum number of batteries in a single system is 50, enabling a maximum energy storage of 192kWh in a 12V system and up to 384kWh in a 24V and 48V system. For comprehensive details about these batteries, visit the Victron Lithium NG battery product page. \u003c\/p\u003e\u003cp\u003eOut of the various BMSes available* for the Lithium NG batteries, the Lynx Smart BMS NG is the most feature-rich and complete option and integrates seamlessly with other M10 products in the Lynx Distributor system. It is available in 500 A (M10) and 1000 A (M10) versions\u003csup\u003e1\u003c\/sup\u003e).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBuilt-in 500 A or 1000 A Contactor \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAvailable in 500 A (M10) and 1000 A (M10) versions\u003c\/li\u003e\n\u003cli\u003eActs as a secondary safety system to protect the battery in case primary controls (ATC, ATD, and\/or DVCC) fail\u003c\/li\u003e\n\u003cli\u003eSuitable as a remote controllable main system switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePre-Charge Circuit \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePrevents high inrush currents when connecting capacitive loads like inverters\u003c\/li\u003e\n\u003cli\u003eEliminates the need for external pre-charging devices\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMonitoring \u0026amp; Control \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBluetooth connectivity for monitoring and control via the VictronConnect App or VE.Can connectivity in combination with GX devices such as the Cerbo GX or Ekrano GX and the VRM portal\u003c\/li\u003e\n\u003cli\u003eReadout of cell voltages and temperatures also on GX devices and the VRM portal\u003c\/li\u003e\n\u003cli\u003eBuilt-in battery monitor provides data such as state of charge, voltage, current, historical data, status info, and more in real-time\u003c\/li\u003e\n\u003cli\u003eDiagnostic at a Glance with Instant Readout\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDVCC Closed Loop Control as well as ATC\/ATD Contacts \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCompatible Victron inverter\/chargers, the Orion XS 12\/12-50A DC-DC battery charger, and solar charge controllers are automatically controlled via a connected GX device and DVCC.\u003c\/li\u003e\n\u003cli\u003eATC\/ATD contacts can be used to control other chargers and loads that have a remote on\/off port\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eProgrammable Relay \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCan be used either as an alarm relay (combined with the pre-alarm) or to control an alternator via its external regulator (ignition cable)\u003c\/li\u003e\n\u003cli\u003eFeatures Alternator ATC mode for safe alternator disconnection before battery disconnects\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAUX Terminal \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOnboard auxiliary power supply (1.1 A @ system voltage) for powering specific loads (i.e. a GX device) post-BMS shutdown\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown of BMS and AUX connection if no charge voltage is detected within 5 minutes after a low voltage event\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVE.Can and NMEA 2000 Data Communication \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEasy connection and communication with GX devices via VE.Can using a standard RJ45 network cable\u003c\/li\u003e\n\u003cli\u003eIntegration into marine networks via NMEA 2000 protocol (requires a VE.Can to NMEA 2000 micro-C male cable)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLynx Distributor Fuse Monitoring \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMonitor fuse status of up to 4 connected Lynx Distributors via VictronConnect or GX devices\u003c\/li\u003e\n\u003cli\u003eReceive alarms in case of blown fuses\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e) Up to 5 BMS-es can be paralleled. This requires a firmware update, expected in Q3 2024.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45255484047542,"sku":"VIC\/LYN034160310","price":884.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/103439XL.jpg?v=1783772637","url":"https:\/\/ampedupmarine.com\/es\/products\/victron-energy-lyn034160310","provider":"Amped Up Marine","version":"1.0","type":"link"}