{"product_id":"maretron-a3708","title":"Mpower J2 Output Mating Connector","description":"\u003cdiv class=\"_chunkWrapper_6ta1u_30\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eMaretron MPower CLMD16 J2 Output Mating Connector — 1m Leads (A3708)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"_chunkWrapper_6ta1u_30\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"0\"\u003eThe \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"4\"\u003eJ2 output Deutsch connector \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"32\"\u003eassembly for the Maretron \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"58\"\u003eMPower CLMD16 — a 12-pin \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"83\"\u003eDeutsch connector with 1m numbered \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"118\"\u003eflying leads that terminates the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"151\"\u003estandard output channel wiring from the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"191\"\u003eCLMD16's J2 port.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"_chunkWrapper_6ta1u_30\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eWhy It's Worth It\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eThe CLMD16's J2 \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"38\"\u003eoutput port handles 12 of the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"68\"\u003e16 output channels (the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"92\"\u003estandard 12A circuits) and uses \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"124\"\u003ea Deutsch DT06-12SA \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"144\"\u003e12-pin connector that isn't \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"172\"\u003eincluded with the base CLMD16 \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"202\"\u003emodule — only the CLMD16-R \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"229\"\u003ebundled kit includes it. If \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"257\"\u003eyou ordered the base \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"278\"\u003eCLMD16 (module only), this is \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"308\"\u003ethe connector you need to \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"334\"\u003ewire your standard output \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"360\"\u003echannels. The 1m pre-made leads \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"392\"\u003eare numbered by breaker \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"416\"\u003eoutput number (not pin \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"439\"\u003eposition) for easy \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"458\"\u003eidentification — splice or connect to \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"496\"\u003ea terminal block per the \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"521\"\u003eCLMD16 installation manual.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"_chunkWrapper_6ta1u_30\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003eUse\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\"\u003ePlug the Deutsch \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"25\"\u003e12-pin connector into the J2 \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"54\"\u003eoutput port on the CLMD16. \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"81\"\u003eThe numbered flying leads \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"107\"\u003ecorrespond to specific breaker \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"138\"\u003eoutput channels — refer to \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"165\"\u003ethe CLMD16 installation \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"189\"\u003emanual for the full wiring map. \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"221\"\u003eOrder alongside A3709 (J1 \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"247\"\u003eoutput connector) and A3710 \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"275\"\u003e(J3 I\/O harness) to complete \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"304\"\u003ethe full wiring harness for a \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"334\"\u003estandalone CLMD16 installation. \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"366\"\u003eNote: a Deutsch HDT-48-00 \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"392\"\u003ecrimp tool is required if you \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"422\"\u003echoose to wire the Deutsch \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"449\"\u003eplug directly rather than \u003c\/span\u003e\u003cspan class=\"_animating_6ta1u_10\" data-newtext-seq=\"475\"\u003eusing this pre-made assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":45225932783798,"sku":"MAR\/A3708","price":65.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/MARA3708_001.jpg?v=1782842088","url":"https:\/\/ampedupmarine.com\/products\/maretron-a3708","provider":"Amped Up Marine","version":"1.0","type":"link"}