{"product_id":"victron-energy-pmp121500100","title":"Victron MultiPlus 12\/500 - 20-16 - 120V - VE. Bus UL Approved","description":"\u003cp\u003e\u003cstrong\u003eMultiPlus 12\/500 - 20-16 - 120V - VE. Bus UL Approved\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the MultiPlus has several advanced features, as outlined below.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eParallel Operation and Three-Phase Capability\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUp to six Multis can operate in parallel to achieve higher power output.  In addition to parallel connection, three units can be configured for three-phase output.  \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePowerControl - Dealing with Limited Generator, Shore Side or Grid Power\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWith the Multi Control Panel, a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.  \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePowerAssist - Boosting the Capacity of Shore or Generator Power\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThis feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load is reduced, the spare power is used to recharge the battery.  \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFour Stage Adaptive Charger and Dual-Bank Battery Charging\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe main output provides a powerful charge to the battery system using advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Charger datasheet and Victron's website under Technical Information. In addition to this, the MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.  \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHigh Start-Up Power\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIt is needed to start high-inrush loads such as power converters for LED lamps, halogen lamps, or electric tools.  \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSearch Mode\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWhen Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode, the Multi, when operating in inverter mode, is switched off in case of no load or very low load and switches on every two seconds for a short period. If the output current exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eProgrammable Relay\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBy default, the programmable relay is set as an alarm relay, i.e. the relay will de-energize in the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost too high, battery voltage almost too low).  \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRemote On\/Off\/Charger On\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThree pole connector.  \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOn-Site System Configuring, Monitoring, and Control\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eAfter installation, the MultiPlus is ready to go. Some settings can be changed with DIP switches. 500\/800\/1200VA models: remote switch\/battery charge voltage\/inverter frequency\/search mode. 1600\/2000VA models:  battery charge voltage\/search mode. For more settings use VE-Config or the VE. Bus Smart dongle.  \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRemote Configuring and Monitoring\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eInstall a Cerbo GX or other GX product to connect to the internet. Operational data can be stored and displayed on Victron's VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed. \u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":45255483621558,"sku":"VIC\/PMP121500100","price":308.55,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/6584\/6966\/files\/102867XL.jpg?v=1783772629","url":"https:\/\/ampedupmarine.com\/products\/victron-energy-pmp121500100","provider":"Amped Up Marine","version":"1.0","type":"link"}