Description
Description
PT-7 Battery Charger
Newmar’s Phase Three Series Battery Chargers employ “Smart” battery charging technology for 12-volt systems aboard marine applications including workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.
A selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. This model is housed in a rugged stainless-steel case with a durable white powder coat finish, and the internal circuitry is polyurethane-coated for maximum corrosion resistance.
Features:
- “Smart” circuitry provides three-stage charging – bulk, absorption, float
- Gel-Cell/Flooded Lead-acid/AGM battery type switch selects optimum charge/float voltages
- Multiple isolated output banks; ammeter indicates total output current. (Except PT-7)
- The optional sensor adjusts output voltage based on battery temperature. (Except PT-7)
- Current limiting prevents damage from overloading
- Clean well-regulated output can be used as a power supply; can power loads directly without a battery in line
- Built to last – rugged stainless-steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry
- ABS-type approval for battery charging and power supplies
Specifications
Specifications
Identification
| MPN | PT-7 |
|---|
Temperature Rating References:
| Temperature | -10 degrees C to +45 degrees C |
|---|---|
| Note 1 | Derate Linearly From 100% @ 0 degrees C to 80% @ -10 degrees C |
Nominal Output Voltages at Gel/Flooded Switch Settings (without Temperature Compensation):
| Gel-Cell | 14.0 VDC Charge @ 50% load and 13.6 VDC Float @ .5 amp load |
|---|---|
| Flooded/AGM | 14.2 VDC Charge @ 50% load and 13.4 VDC Float @ .5 amp load |
Compliance References:
| CG | USCG CFR 183.410 (Ignition protected) |
|---|---|
| CE | Carries the CE mark |
| ABS | PT Series meet SVR 2009 4-8-3/5.9, Under 90 meters Rules 2006 4-6-4/7.19, and HSNC 2007 4-8-3/5.13 |
General
| Protection | Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield |
|---|
Reviews (0)
Reviews (0)
In The Box
In The Box
In The Box:
Package Dimensions:
Available Method:
Support
Support
* ALL WARRANTY IS THROUGH MANUFACTURE *