Actisense NMEA2000 Mid Bulk Cable Reel - 100M

SKU: ACT/A2K-BULK-100MID
Precio de venta $58500 Precio normal $65000

Need This Product Installed?

We Offer Mobile Installation From West Palm Beach - Fort Pierce, FL

Click Here To Set Up Your Installation

Descripción

NMEA2000 Mid Bulk Cable Reel - 100M

This cable can be used to create or extend an NMEA 2000® network of flexible lengths to suit any installation. The cable is ideal for use with any of the Actisense A2K Product range for building networks.

The cable is LSZH certified to give installers and end users maximum peace of mind and an extra layer of safety.

The Actisense range of NMEA 2000® connectors and cables has been designed using our specialist interconnectivity and NMEA knowledge. All Actisense cables and connectors are NMEA 2000® approved.

The NMEA 2000® cable includes five wires within a single waterproof cable: power and ground wires, two signal wires, and a drain wire. The drain wire connects to the cable shield, which protects the signal, power, and ground wires from external Radio Frequency Interference (RFI) and helps reduce RFI emission from the cable.

NMEA 2000® Mid cable can be used to create a backbone up to 250 meters in length, and offers a current capacity of 4A with Micro connectors, or 8A with Mini connectors.

Specifications

Identification

MPN A2K-BULK-100MID
Barcode 5060998710812

Cable

Rated Voltage 60V DC
Rated Current 8A
Braid Material 37 AWG tinned copper
Braid Coverage 65% Nom.
Jacket Material LSZH Purple (RAL4008)
Jacket Outer Diameter 8.2mm
Overall DCR (braid + tape + drain) 3.2Ω / 1000ft (10.5mΩ/M)
Reel Length 100m
Reel Weight 13-14kg

Power Pair

Conductor 16 AWG (19-strand tinned copper)
Insulation 0.17 mm Nom. LSZH
Diameter 1.85mm Nom.
Colors Red & Black
Shield AL Mylar tape over pair
DC Resistance 4.26Ω / 1000ft (14mΩ/M)

Data Pair

Conductor 20 AWG (19-strand tinned copper)
Insulation 0.79 mm Nom. Foam PE
Diameter 2.49mm Nom
Colors Blue & White
Shield AL Mylar tape over pair
Impedance 120Ω ±10% @ 1MHz
DC Resistance 10.9Ω / 1000 ft (35.8mΩ/M)
Attenuation @ 125 kHz 0.29dB / 100ft
Attenuation @ 500 kHz 0.50dB / 100ft
Attenuation @ 1 MHz 0.70dB / 100ft

Drain

Conductor 20 AWG (19-strand tinned copper)
DC Resistance 10.9Ω / 1000ft (35.8mΩ/M)

Approvals and Certifications

Operating Temperature -20°C to +70°C
Storage Temperature -40°C to +85°C
Note 1 NMEA 2000 Approved
Note 2 RoHS Compliant
Note 3 UL Certified (E137250), (UL13)
Note 4 LSZH to IEC 60754-1/2 & IEC 61034-1/2

Reseñas (0)

In The Box

In The Box:

Package Dimensions:

14" x 14" x 12"

Available Method: Ground